📘 GE Panametrics Flue Gas Analyzer Series 300 – Model FGA 300H (FGA300H-10-41-60-10-0)
The GE Panametrics FGA 300H is a microprocessor-based flue gas analyzer designed for continuous monitoring of combustion processes in industrial applications. It provides real-time analysis of oxygen and combustibles concentrations, ensuring optimal combustion efficiency and compliance with environmental regulations.
🔧 Key Features
- Dual Measurement Capability: Simultaneous measurement of oxygen and combustibles (CO, CH₄, etc.) concentrations.
- Real-Time Response: Rapid detection of changes in flue gas composition, facilitating immediate adjustments to combustion processes.
- Analog Output Options: Configurable analog outputs (0-20 mA, 4-20 mA, 0-10 V, 2-10 V) for integration with control systems.
- User-Friendly Interface: Equipped with a digital display and intuitive controls for ease of operation and calibration.
- Robust Design: Built to withstand harsh industrial environments, ensuring long-term reliability.
📊 Technical Specifications
Parameter | Value |
---|---|
Model | FGA 300H |
Product Code | FGA300H-10-41-60-10-0 |
Measurement Range | O₂: 0-25%, Combustibles: 0-1000 ppm |
Response Time | < 10 seconds |
Analog Outputs | 0-20 mA, 4-20 mA, 0-10 V, 2-10 V |
Power Supply | 24 VDC ±10% |
Operating Temp. | 0°C to +50°C |
Storage Temp. | -20°C to +60°C |
Dimensions (L×W×H) | 350 mm × 240 mm × 150 mm |
Weight | 2.9 kg |
Enclosure Rating | IP65 |
Certifications | CE, UL, CSA |
⚙️ Applications
- Boiler and Furnace Monitoring: Ensures efficient combustion by continuously analyzing flue gas composition.
- Environmental Compliance: Assists in meeting emission standards by providing accurate gas concentration data.
- Process Optimization: Facilitates adjustments to combustion processes for improved energy efficiency and reduced emissions.
🛠️ Installation & Maintenance
- Installation: Mount the analyzer in a location with adequate ventilation and away from direct heat sources. Ensure proper alignment of sample gas inlet and outlet ports.
- Calibration: Perform calibration using certified calibration gases. Follow the manufacturer’s guidelines for calibration procedures.
- Maintenance: Regularly inspect and clean the sensor and sample gas pathways to prevent blockages and ensure accurate readings. Replace consumables as per the maintenance schedule.
🔗 Useful Links
📑 Recommended Similar Products
Model | Description | Link |
---|---|---|
FGA 300H | Dual gas analyzer for oxygen and combustibles | View More |
FGA 300V | Vertical flue gas analyzer for high-temperature applications | View More |
FGA 300VX | Explosion-proof version for hazardous environments | View More |
FGA 300X | Extended range analyzer for specialized applications | View More |
If you require further information or assistance with selecting the appropriate model for your specific application, please feel free to contact us.